AAI ORIGINAL English Verison N1201SA N1201SA+ 34.375MHz-2.7GHz UV RF Vector Impedance ANT SWR Antenna Analyzer Meter Tester
94
Yakavimbiswa Yakachengeteka Kuongorora

Zvinhu zvinodzoserwa zvinogamuchirwa mukati memazuva makumi mana kana iri zuva rekugamuchira zvinhu. Zvinhu zvakagadziridzwa hazvigone kudzoserwa kana kuchinjaniswa. Zvinhu zvakatengwa negift card yemahara zvinogona kuchinjaniswa chete; hazvigone kudzoserwa mari.
Chipo Chemahara
Kugamuchirwa kuRoymall, webhusaiti yako yehunyanzvi yekutenga zvipo zvepamusoro zvedhipatimendi. Tinokoshesa uye tinotenda rutsigiro rwako, uye tinoda kuratidza kutenda kwedu nekuwedzera chimwe chinhu chinonakidza kune zvamunotenga. Paunotenga nesu, haungongowana zvigadzirwa zvepamusoro zvinovandudza mararamiro ako, asi uchagamuchirawo chipo chakasarudzika chemahara nechero odha yaunoisa. Wagadzirira kuongorora kuunganidzwa kwedu uye kuwana zvipo zvako zvakakwana? Tarisa sarudzo yedu yezvinhu zvedhipatimendi repamusoro, isa odha yako, uye tarisira kunakidzwa kwechipo chako chemahara kusvika pamwe nekutenga kwako.Mutemo Wekutumira
Tichashanda nesimba kutumira zvinhu kwauri mushure mekugamuchira maodha ako uye kuve nechokwadi chekuti zvinosvika zvakachengeteka. Ruzivo rwekutumira rwuchapihwa muemail yako yekusimbisa.Kazhinji, maodha anogadziriswa mukati memazuva maviri.Pasi pemamiriro ezvinhu akakosha, zvinononoka seinotevera: Paunoisa odha neMugovera, Svondo kana mazororo, zvinononoka kwemazuva maviri.Kazhinji, zvinoda mazuva mashanu kusvika manomwe ekushanda (Muvhuro kusvika Chishanu) pasina kukanganiswa nekunonoka kwendege kana zvimwe zvinhu zvemamiriro ekunze.Sezvo basa redu rekutumira riri pasi rose, nguva dzekutumira dzinoenderana nenzvimbo yako saka zvingatora nguva shoma uye ndapota mirira nemoyo murefu kana iwe uri mumatunhu ari kure kana nyika.1. Kudzoserwa & Kuchinjaniswa Mutemo
Tinogamuchira chete zvinhu zvakatengwa kubva roymall.com. Kana iwe ukatenga kubva kune vedu vekutengesa kana vamwe vatengesi, haugone kuzvidzosera kwatiri. Zvinhu zvekupedzisira kutengeswa kana zvipo zvemahara hazvigamuchirwe kudzoserwa.Kuti ukwanise kudzosa, chinhu chako chinofanira kunge chisina kushandiswa uye chiri mumamiriro akafanana neawachigamuchira. Chinofanirawo kunge chiri mupakeji yepakutanga.Mushure mekugamuchira mirairo yekudzosa kubva kwatiri, ndapota pakeja zvinhu zvako zvakadzoserwa uye donhedza pasuru yako kuposvo yemuno kana imwe courier.Tichagadzirisa chinhu chako chakadzoserwa kana kuchinjaniswa mukati memazuva matatu kusvika mashanu ekushanda mushure mekunge tagamuchira. Mari yacho ichagadziriswa uye yozopihwa otomatiki kune yako yekutanga nzira yekubhadhara.Hapana kudzoserwa kana kuchinjaniswa kunogona kugamuchirwa kana chigadzirwa chakagadzirwa netsika, kusanganisira saizi yakagadziridzwa, ruvara rwakagadziridzwa, kana kudhinda kwakagadziridzwa.Unoda rumwe rubatsiro, ndapota taura nesu. service@roymall.com kana Whatsapp: +86193598494712.Mutemo Wekudzoserwa Mari
Uchawana mari yakazara kana 100% kiredhiti yechitoro mushure mekunge tagamuchira pasuru yakadzoserwa uye tikaiona. Mari yacho ichagadziriswa uye yozopihwa otomatiki kune yako yekutanga nzira yekubhadhara.Ndapota cherechedza kuti mitengo yekutumira uye chero mitero kana mubhadharo haidzoserwe. Mari yekuwedzera yekutumira haidzoserwe kana pasuru yatotumirwa. Iwe une basa rekubhadhara aya mitero uye isu hatikwanise kuregerera kana kudzosera, kunyangwe odha ikadzoserwa kwatiri.Kana tangogamuchira uye tasimbisa chinhu chako chakadzoserwa, tichakutumira email kukuzivisa kuti tagamuchira chinhu chako chakadzoserwa. Tichakuzivisawo nezvekubvumidzwa kana kurambwa kwemari yako.Kana uine chero matambudziko maererano nemaitiro ekudzoserwa mari, ndapota taura nesu. service@roymall.com kana Whatsapp: +8619359849471
Description:
- This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration
The default boot into single-point measurement interface.
Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.
Startup and shutdown:
Hold down the CTRL key off press the power switch button.
The boot state, long press (2S above) the switch button, after the release, the instrument will shut down
The boot state, long press (2S above) the switch button, after the release, the instrument will shut down
Recommend the use:
1, in order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.
2, try to use good quality RF cable and connectors.
3, calibrated cable marked to the next may not need to calibrate and direct use.
4, test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.
5, measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.
6, if the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis
Specification:
working currency: 140MHz~2700MHz
stepped frequency: 1kHz
Display: 2.4inch TFT
resolution: 320*240(QVGA)
battery: 2000mAH(7.4Wh)
power consumption: <1.5W
charge current: 400mA
charge port: USB
Auto power off can be set 5-60minutes
Measured parameters:
resistence reactance standing wave s11
resolution ratio: 4 number
frequency accuracy: about 5ppm
Connector: SMA-K
Measurement range:
impedance: 0.1~1000
standing wave: 1.000~65
s11(dB): 0dB~-60dB
Working temperature: 0~40 degree
Package included:
1 x Original N1201SA Antenna Analyzer Meter
1 x English User Manual
- This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration
The default boot into single-point measurement interface.
Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.
Startup and shutdown:
Hold down the CTRL key off press the power switch button.
The boot state, long press (2S above) the switch button, after the release, the instrument will shut down
The boot state, long press (2S above) the switch button, after the release, the instrument will shut down
Recommend the use:
1, in order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.
2, try to use good quality RF cable and connectors.
3, calibrated cable marked to the next may not need to calibrate and direct use.
4, test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.
5, measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.
6, if the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis
Specification:
working currency: 140MHz~2700MHz
stepped frequency: 1kHz
Display: 2.4inch TFT
resolution: 320*240(QVGA)
battery: 2000mAH(7.4Wh)
power consumption: <1.5W
charge current: 400mA
charge port: USB
Auto power off can be set 5-60minutes
Measured parameters:
resistence reactance standing wave s11
resolution ratio: 4 number
frequency accuracy: about 5ppm
Connector: SMA-K
Measurement range:
impedance: 0.1~1000
standing wave: 1.000~65
s11(dB): 0dB~-60dB
Working temperature: 0~40 degree
Package included:
1 x Original N1201SA Antenna Analyzer Meter
1 x English User Manual
Tools, Industrial & Scientific Ranking
- This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration
The default boot into single-point measurement interface.
Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.
Startup and shutdown:
Hold down the CTRL key off press the power switch button.
The boot state, long press (2S above) the switch button, after the release, the instrument will shut down
The boot state, long press (2S above) the switch button, after the release, the instrument will shut down
Recommend the use:
1, in order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.
2, try to use good quality RF cable and connectors.
3, calibrated cable marked to the next may not need to calibrate and direct use.
4, test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.
5, measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.
6, if the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis
Specification:
working currency: 140MHz~2700MHz
stepped frequency: 1kHz
Display: 2.4inch TFT
resolution: 320*240(QVGA)
battery: 2000mAH(7.4Wh)
power consumption: <1.5W
charge current: 400mA
charge port: USB
Auto power off can be set 5-60minutes
Measured parameters:
resistence reactance standing wave s11
resolution ratio: 4 number
frequency accuracy: about 5ppm
Connector: SMA-K
Measurement range:
impedance: 0.1~1000
standing wave: 1.000~65
s11(dB): 0dB~-60dB
Working temperature: 0~40 degree
Package included:
1 x Original N1201SA Antenna Analyzer Meter
1 x English User Manual